Sign In | Join Free | My himfr.com
Home > MPPT VFD Solar Pump Inverter >

LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance from wholesalers
     
    Buy cheap LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance from wholesalers
    • Buy cheap LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance from wholesalers
    • Buy cheap LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance from wholesalers
    • Buy cheap LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance from wholesalers
    • Buy cheap LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance from wholesalers

    LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-PV
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 15000pcs per Month
    Delivery Time : depend on the order quantity
    MOQ : Negotiable
    • Product Details
    • Company Profile

    LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance

    LCD MPPT VFD Solar Pump Inverter GPRS solar vfd for pump solar irrigation system


    VEIKONG IS Solar Ac Pump Controller chinese manufacturer


    Performance features:(220v 0.75kw-75kw, 380v 0.75kw-250kw)

    Product Details and Features:


    1. Support single phase/three phase 220V, and three phase 380V solar water pump inverter, power from 0.75KW to 160KW.


    2. Simply connect the photovoltaic panel to the solar water pump inverter, and the PV pump c be automatically started after power-on.


    3. It has protection functions such as PV over-voltage protection, over-temperature automatic protect, etc., which can effectively extend the life of the product.


    4. Ensure solar power tracking efficiency can reach 99%.


    5. All series of products can realize automatic switching of PV DC input and grid AC input, which can meet 24 hours of no care work.


    6. Supports IP20 and IP65 grade cabinet solutions.


    7. LCD display, GPRS module, Output reactor Accessories.


    Electrical Specifications


    PV input
    Maxiumum input DC voltage400V DC
    Recommended MPPT voltage range250~350V DC
    Recommended input Operation Voltage310V DC
    Grid or backup generator input
    Input voltageSingle phase 220V(-15%~30%)
    Output Specification
    Rated output voltage3PH 220V
    Output frequency0~500.00Hz (default: 0~50.00Hz)
    380V Solar Pumping Inverter
    Input Specification
    PV input
    Maxiumum input DC voltage800V DC
    Recommended MPPT voltage range450~650V DC
    Recommended input Operation voltage540V DC
    Grid or backup generator input
    Input voltageThree phase 380V(-15%~30%)
    Output specification
    Rated ouput voltage3PH 380V
    Output frequency0~500.00Hz (default: 0~50.00Hz)
    Protection
    Built-in ProtectionLighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc.

    General Parameters
    Application siteNo direct sunshine, no dust,corrosive gas,combustible gas, oil mist, steam,dripping or salinity etc.
    Altitude0~2000m
    Derated use above 1000m, per 100m, the rated output current decrease 1%
    Environment Temperature-10°C~40°C (Environment Temperature be 40°C~50°C, please keep derated use)
    Humidity5~95%, non-condensation
    Vibrationless than 5.9 m/s²(0.6G)
    Storage Temperature-20°C~+70°C
    EfficiencyRated Power Run≥93%
    InstallationWall or rail mounting
    Protectiion GradeIP20
    CoolingForced Air Cooling


    Accessories:


    1. GPRS (support 2g/3g/4g internet)


    2. Output reactor


    3. LCD keypad








    Model Range

    Drive ModelRelated VoltageMax DC input voltage (V)Rated output current (A)Applicable water pump (KW)SIZE
    VFD500M-20T00150-PV220V80071.5SIZE A
    VFD500M-20T00220-PV220V80010.62.2SIZE A
    VFD500M-40T00150-PV380V8004.21.5SIZE A
    VFD500M-40T00220-PV380V80062.2SIZE A
    VFD500-20T00150-PV220V80071.5SIZE A
    VFD500-20T00220-PV220V80010.62.2SIZE A
    VFD500-20T00400-PV220V800174SIZE A
    VFD500-40T00150-PV380V8004.21.5SIZE A
    VFD500-40T00220-PV380V80062.2SIZE A
    VFD500-40T00400-PV380V8009.44SIZE A
    VFD500-40T00550-PV380V800135.5SIZE B
    VFD500-40T00750-PV380V800177.5SIZE B
    VFD500-40T01100-PV380V8002511SIZE C
    VFD500-40T01500-PV380V8003215SIZE C
    VFD500-40T01850-PV380V8003818.5SIZE D
    VFD500-40T02200-PV380V8004622SIZE D
    VFD500-40T03000-PV380V8006030SIZE E
    VFD500-40T03700-PV380V8007537SIZE E
    VFD500-40T04500-PV380V8009645SIZE F
    VFD500-40T05500-PV380V80011255SIZE F
    VFD500-40T07500-PV380V80015075SIZE G
    VFD500-40T09000-PV380V80017690SIZE G
    VFD500-40T11000-PV380V800210110SIZE H
    VFD500-40T13200-PV380V800253132SIZE I
    VFD500-40T16000-PV380V800304160SIZE I
    VFD500-40T18500-PV380V800340185SIZE J
    VFD500-40T20000-PV380V800377200SIZE J

    MPPT introduction

    MPPT means Maximum Power Point Tracking; it’s a special function for solar system, which is used to get the

    maximum possible power from one or more photovoltaic devices, typically solar panels. Solar panels have a

    complex relationship between solar irradiation, temperature and total resistance that produces a nonlinear output

    efficiency which can be analyzed based on the I-V curve. It is the purpose of the MPPT system to sample the output

    of the cells and apply the proper resistance (load) to obtain maximum power for any given environmental conditions.


    By adopting this technology in the solar pump inverter, it increases the working efficiency of solar panels,

    and also adjusts the output frequency of solar pump VFD based on the sunshine strength; make sure the system

    always works at an optimum condition.


    Quality Control
    VEIKONG solar pump VFDs have passed comprehensive test process during manufacturing.

    R&D test: test the hardware and software performance, to make the design more optimization, makes sure the products have excellent

    performance before production;


    Board test: test the performance of every board in our products, to reduce product defective rate;

    IQC: take strict quality inspection for every income components, to ensure every income components are qualified.


    Aging test: make the solar pump VFDs at run status, put them in the aging test house at 50°C for 48 hours, to remove every unqualified products.


    Load test: the last and the most important test, add different load to the solar pump VFDs, test their input and output value, to check their

    working performance. unqualified products will be removed from the team.

    By applying such strict testing process, VEIKONG ensures every outgoing solar pump VFD has excellent quality.




    Quality LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Veikong Electric Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)