Sign In | Join Free | My himfr.com
Home > Solar Water Pump Controller >

0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99%

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99% from wholesalers
     
    Buy cheap 0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99% from wholesalers
    • Buy cheap 0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99% from wholesalers

    0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99%

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-PV
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 15000pcs per Month
    Delivery Time : depend on the order quantity
    • Product Details
    • Company Profile

    0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99%

    0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99%


    160kw solar pump inverter with MPPT 99% PID controller solar vfd


    Why chose VEIKONG?

    1. Infineon brand IGBT/Fuji IGBT, enduree temperature 175°C
    2. Two-lines LED keypad/LCD kaypad
    3. Fan: 70 000 hours using life
    4. Capacitor: 50 000 hours using life
    5. Input phase lacking protection
    6. Output short circuit protection
    7. Overvoltage protection
    9. 10 000-15 000pcs per month production ability
    10. 500pcs stock below 90KW
    11. CE ISO certification, TUV SGS authority
    12. Strong RD department, can update software


    Key Features:

    1, Support single phase/three phase 220V, and three phase 380V solar water pump inverter, power from 0.75kW to 160KW

    2, Simply connect the photovoltaic panel to the inverter, no need to set any parameters.

    3, It has protection functions such as overvoltage protection, overcurrent protection, dry runing protection, full water protection.


    4, Advanced MPPT algorithm. Ensure solar power tracking efficiency can reach 99.99%

    5, Supports optional GPRS module, which can realize remote monitoring function of computer webpage and mobile APP

    6, Support PV DC input and grid AC input at same time, which can meet 24 hours of no care work

    7, Support LCD keypad, it is easier to monitor system situation.



    Electrical Specifications and Power degree

    220V

    380V

    Max input DC voltage

    450V

    810V

    DC voltage range

    150~450VDC

    300~810VDC

    Normal working DC voltage

    260V-400V

    400V-650V

    Recommended input mppt voltage

    330V

    550V

    MPPT efficiency

    >99%

    Rated output voltage

    1/3-phase 220VAC

    3-phase 380-480VAC

    Output frequency range

    50/60Hz

    Max efficiency of the machine

    99%

    Ambient temperature range

    -10 °C~50 °C, derating if the temperature is above 40 °C

    Cooling method

    Air cooling

    Protection degree

    IP20/IP21

    Altitude

    Below 1000m; above 1% for every additional 100m.

    Standard

    CE/ROHS



    Accessories:

    1. GPRS (support 2g/3g/4g internet)



    2. LCD keypad





    3. Output Reactor




    VFD500-PV solar pump inverter picture:


    Connect wire diagram


    Techincal Parameters:


    1. Wake up and sleep function parameters:


    P47.05Light detection thresholdIf the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop0Hz
    P47.06Light detection timeSee P47.05 for explanation.60s
    P47.07Light weak wake up timeAfter the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues.600s

    2. Dry runing protection function parameters:


    P24.12Dry run/Unload protection option

    0: No offload detection is performed;

    1: Enable dry run detection

    1
    P24.13Dry run/Unload detection level

    0.0 to 200.0%

    The percentage of motor rated current.

    0.0%
    P24.14Dry run Unload detection time0.000s~60.000s30.000s
    P24.15Unload detection offset frequency

    0.00Hz~Fmax

    Detection frequency=Fmax-P24.15


    5.00Hz
    P24.16Reset time of dry run protection0.0~6000.0240.0s
    P23.21Dry run detection mode

    0000:Coast stop

    1000:Fast stop

    3000:Continue to run

    0000

    FAQ
    1. How to achieve Automatic start after stop?
    If it is controlled by keyboard no need to set any parameter. If you want to control by external switch
    As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com
    and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop
    2. How to design solar PV water pump system?
    Key point: the rated VOC and VMP and power of the PV Array need to match the input range of
    the inverter. If needed, we will provide technical support online.
    3. How to use a float in the water tank to stop the pump if the tank is full?
    If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3
    4. How to set minimum frequency ( for example) 30hz and maximum 50HZ
    Set P47.05=30HZ and 47.06 to some time and 47.07 to some time. Please refer to details of P47.05-47.07


    Quality 0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99% for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Veikong Electric Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)