Sign In | Join Free | My himfr.com
Home > MPPT VFD Solar Pump Inverter >

External Switch Control MPPT VFD Solar Pump Inverter 1.5kw-11kw for Pumping

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap External Switch Control MPPT VFD Solar Pump Inverter 1.5kw-11kw for Pumping from wholesalers
     
    Buy cheap External Switch Control MPPT VFD Solar Pump Inverter 1.5kw-11kw for Pumping from wholesalers
    • Buy cheap External Switch Control MPPT VFD Solar Pump Inverter 1.5kw-11kw for Pumping from wholesalers
    • Buy cheap External Switch Control MPPT VFD Solar Pump Inverter 1.5kw-11kw for Pumping from wholesalers
    • Buy cheap External Switch Control MPPT VFD Solar Pump Inverter 1.5kw-11kw for Pumping from wholesalers
    • Buy cheap External Switch Control MPPT VFD Solar Pump Inverter 1.5kw-11kw for Pumping from wholesalers

    External Switch Control MPPT VFD Solar Pump Inverter 1.5kw-11kw for Pumping

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-PV
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 15000pcs per Month
    Delivery Time : depend on the order quantity
    • Product Details
    • Company Profile

    External Switch Control MPPT VFD Solar Pump Inverter 1.5kw-11kw for Pumping

    99% MPPT VFD Solar Pump Inverter 1.5kw To 11kw For Pumping System


    DC AC MPPT Solar Pump Inverter 1.5kw 2.2kw 4kw 5.5kw 7.5kw 11kw VFD


    VEIKONG VFD500-PV solar pumping inverter is specially designed for watering system. A high converting efficiency of 99% and advanced MPPT technology make the solar energy fully used. It converts DC power into AC to drive all kinds of motors. The intelligent design protects the pumps from many abnormal cases, such as over-loading, over-voltage, dry-running, over-heating,low frequency and et
    ● Easy to use
    Simply connect the photovoltaic panel to the inverter, no need to set any parameters, and the PV pump can be automatically started after power-on
    ● Multiple protection measures It has protection functions such as PV over-voltage protection, PV polarity reverse connection alarm, over-temperature automatic derating, etc., which can effectively extend the life of the product
    ● Advanced MPPT algorithmEnsure solar power tracking efficiency can reach 99%
    ● GPRS remote monitoringSupports optional GPRS module, which can realize remote monitoring function of computer webpage and mobile APP
    ● AC/DC switching schemeAll series of products can realize automatic switching of PV DC input and grid AC input, which can meet 24 hours of no care work

    1. How to achieve Automatic start after stop?

    If it is controlled by keyboard no need to set any parameter. If you want to control by external switch

    As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop


    2.If pump is 60HZ frequency, how to set max frequency?

    Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.

    Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single phase with capacitor ,set P00.11=22;If your motor is single phase without capacitor ,set P00.11=32VEIKONG solar pump inverter applicationVEIKONG solar application

    Electrical Specifications



    220V

    380V

    Max input DC voltage

    450V

    810V

    DC voltage range

    150~450VDC

    300~810VDC

    Normal working DC voltage

    260V-400V

    400V-650V

    Recommended input mppt voltage

    330V

    550V

    MPPT efficiency

    >99%

    Rated output voltage

    1/3-phase 220VAC

    3-phase 380-480VAC

    Output frequency range

    50/60Hz

    Max efficiency of the machine

    99%

    Ambient temperature range

    -10 °C~50 °C, derating if the temperature is above 40 °C

    Cooling method

    Air cooling

    Protection degree

    IP20/IP21

    Altitude

    Below 1000m; above 1% for every additional 100m.

    Standard

    CE/ROHS



    Accessories:


    1. GPRS (support 2g/3g/4g internet)


    2. Output reactor


    3. LCD keypad


    VEIKONG LCD display


    VEIKONG study famous brands inverter advantages





    For 220V single phase motor connection

    1: Single phase asynchronous motor wiring method (without starting capacitor):

    Notice: U is connected to the common end of the starting winding and the working winding, V is connected to the starting winding, and W is connected to the working winding;


    Single-phase asynchronous motor if the rotary steering is not correct, you can change the V and W wiring or set P22.13=1.


    First solution: Set parameter P11.01=1 (Single phase motor type without capacitor) or second solution: set P00.11=31 if your motor frequency is 50 hz or set P00.11=32 if your motor frequency is 60HZ


    For 220V single phase motor connection

    2: Single-phase asynchronous motor wiring method (with capacitor)


    Notice1: First solution: Connect motor cable to power terminal U and V and enter BSC mode to Set parameter P23.15=0(output phase loss shielding protection) or second solution: set macro P00.11=21 if your motor frequency is 50HZ or set P00.11=22 if your motor frequency is 60HZ



    Quality External Switch Control MPPT VFD Solar Pump Inverter 1.5kw-11kw for Pumping for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Veikong Electric Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)