Sign In | Join Free | My himfr.com
Home > Solar Water Pump Controller >

CE High Flow 4000W Solar Water Pump Controller Solar Variable Frequency Drive

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap CE High Flow 4000W Solar Water Pump Controller Solar Variable Frequency Drive from wholesalers
     
    Buy cheap CE High Flow 4000W Solar Water Pump Controller Solar Variable Frequency Drive from wholesalers
    • Buy cheap CE High Flow 4000W Solar Water Pump Controller Solar Variable Frequency Drive from wholesalers
    • Buy cheap CE High Flow 4000W Solar Water Pump Controller Solar Variable Frequency Drive from wholesalers

    CE High Flow 4000W Solar Water Pump Controller Solar Variable Frequency Drive

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-PV
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 15000pcs per Month
    Delivery Time : 3 days, depend on the order quantity
    • Product Details
    • Company Profile

    CE High Flow 4000W Solar Water Pump Controller Solar Variable Frequency Drive

    Mppt 0.75kw-160kw solar vfd solar pump inverter for ac pump PMSM pump


    With the price of solar panels dropping over the last couple of years, plus government subsidies for using solar power systems,

    solar power adoption will become more popular and available for all.

    Veikong's solar pumping solution offers high reliability and efficiency in a compact design and simple structure.

    Weighing both productivity and eco-friendliness, Veikong's solution provides a practical alternative for energy-intensive farming in places where power infrastructure deployment is challenging. Veikong is dedicated to providing innovative, clean and energy-efficient solutions for a better tomorrow


    Key Advantages:


    1, The power range is from 220V 0.75kw to75kw, and 380v 0.75kw to 160kw


    1, MPPT 99%, adjust the output frequency to the appropriate frequency in real-time.


    2, Adjust water outflow of pumps quickly on basis of sunlight intensity change.


    3, Light weak protection, dry run and low voltage,full water warning, overvoltage and overtemperature protection.


    4, New keyboard design, support optional LCD keypad, simple appearance, and easy operation.


    5, Automatic running without any commisioning in keypad control and GPRS monitoring option(as option).


    6, Support AC pump and PMSM pump.


    Support optional LCD keypad


    Support optional GPRS Module

    Product application pictures
    CE High Flow 4000W Solar Water Pump Controller Solar Variable Frequency DriveCE High Flow 4000W Solar Water Pump Controller Solar Variable Frequency Drive

    Solar pump special parameter User mode fast quick start


    Function codeNameDescriptionDefaultProperty
    47 Group solar pumping special group
    P00.03RESET

    0:NO ACTION

    11:Restore default parameter except for motor parameter and auto-tune related parameter and factory parameter

    12:Restore default to factory parameter 13:Clear tripping record

    0
    P00.06Source of the Operation Command

    0:keypad

    1:terminal

    2:communication

    Ø Command source: run,stop,forward,reverse,jog,fast brake stop.etc

    0
    P00.07Numeric frequency setting00.00Hz~maximum frequency50.00Hz
    P00.11Application Macro

    00001:Output three phase 50HZ

    00002:Output three phase 60hz

    00021:Output single phase with capacitor 50hz

    00022:Output single phase with capacitor 60hz

    00031:Output single phase without capacitor 50hz

    00032:Output single phase without capacitor 60hz

    00000
    P01.06Maximum frequency10.00~600.00Hz50.00Hz
    P01.08Upper limit frequencyLower limit frequency-maximum frequency50.00Hz
    P07.03Relay 1 Output terminal function group(T1A T1B T1C)

    0:No function

    1:READY

    2:RUN

    3:Error1(stop fault)

    4:Error2(same as Error1 except undervoltage)

    5:Warning output(fault but in running)

    3
    P11.01AC asynchronous motor TYPE

    0:Three phase AC asynchronous motor

    1:Single phase AC asynchronous motor without starting capacitor

    0
    P11.02Motor rated power

    0.1kW~710.0kW

    Ø when power is less than 1kw ,0.75kw set to 0.8 as per round up principle ,0.55kw motor set 0.6

    Ø when change motor rated power,AC drive will automatically set other parameter of motor name plate and motor model parameter be careful to use

    Depend
    P11.03Motor rated voltage10V~2000VDepend
    P11.04Motor rated current

    P11.02<30kW:0.01A

    P11.02>=30kW:0.1A

    Depend
    P11.05Motor rated frequency1.00Hz~600.00Hz50.00Hz
    P11.06Motor rated RPM1~60000rpmDepend
    P21.00Monitoring display

    0:Standard mode (display frequency only)

    1:Automatic scrolling display(Check 3.1 in detail )it show hz,current,power and voltage

    0
    P23.15Output phase loss function0.0-30%, 0% means output phase detections shielded30%
    r27.15Accumulative running time

    Unit:hour


    P47.00Solar pump Mppt function enable

    0: invalid

    The parameters behind the 47 group cannot be changed!

    1: Enable, to enable the special mppt function of the PV pump inverter


    1
    P47.01

    Solar pump control mode


    Units digit’s: Startup mode

    0: Manual start, the start mode is determined by P00.06;

    1: automatic start,

    When P00.06 change, the association changes here.

    P00.06=0, when inverter starts and stops by keypad control, it is automatically modified to 1-automatic start

    P00.06=1, when inverter starts and stops by terminal control.it is automatically changed to 0-manual start

    Ten digit’s: MPPT function

    0: MPPT is disabled; CVT control is used (voltage is given as P47.04).

    1: Enable MPPT.

    Hundred’s unit automatic switching function

    0: prohibited

    1: enable

    Automatic switching is enabled, when the light is weak, it will automatically switch to the electric supply, and the MPPT function is disabled at this time.

    011
    P47.03Automatic start timingIn auto start mode, set the time from power on to start. It is also waiting time to start600
    P47.04MPPT starting voltage

    Set the starting voltage of the MPPT algorithm.

    When the MPPT function is disabled, this value is the reference voltage.

    305V(530V)
    P47.05Light detection threshold

    If the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop

    If automatic switching is enabled, it will switch to ac grid operation, and the MPPT function will be disabled

    0Hz
    P47.06Light detection timeSee P47.05 for explanation.60s
    P47.07Light weak wake up time

    After the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues.

    When the automatic switching is enabled, after switching into the electric supply operation for this time, it will try to switch into the photovoltaic operation.

    600s
    P47.08MPPT tracking step lengthThe amount of change in the bus voltage during an MPPT cycle. The larger the value, the faster the maximum power point is found, but the lower the accuracy of the maximum power point.2V
    P47.09Regulator proportional gain0.001~1.00 It is for immediate response speed, it is not recommended to change0.05
    P47.10Regulator integral gain0.001~0.100 tracking response.it is not recommended to change0.05
    P47.28Starting coefficient0.000~1.0000.850
    P47.30Fast speed function

    Unit digit:fast starting

    0:Disable 1:Enable

    Ten digit:Fast mppt tracking

    0:Disable 1:Enable