    Brand Name : VEIKONG
    Model Number : VFD500-PV
    Certification : CE
    Price : Negotiable
    Payment Terms : Western Union, T/T, L/C, PayPal
    Supply Ability : 15000pcs per Month
    Delivery Time : 3 days, depend on the order quantity
    • Product Details
    • Company Profile

    0.75KW-4KW Single Phase Solar Pump Inverter For Solar Irrigation System

    0.75KW 1.5KW 2.2KW 4KW Single Phase Solar Pump Inverter For Solar Irrigation System

    Product Features:


    1, Support both DC/AC input and 220V level


    2, Support both single phase output and three phase output


    3, Built-in C3 EMC filter for better harmonic and VDR grounding conforming


    4, Widely working voltage can work as low as 350V-800VDC for 380V level and 200-410VDC for 220V level


    5, Support input power from solar panels, on-grid power, generator..


    6, Can be used with solar panels in day time, at night with on-grid power or generator


    7, Can switch between solar panels and on-grid power automatically


    Electrical Specifications



    220V

    380V

    Max input DC voltage

    450V

    810V

    DC voltage range

    150~450VDC

    300~810VDC

    Normal working DC voltage

    260V-400V

    400V-650V

    Recommended input mppt voltage

    330V

    550V

    MPPT efficiency

    >99%

    Rated output voltage

    1/3-phase 220VAC

    3-phase 380-480VAC

    Output frequency range

    50/60Hz

    Max efficiency of the machine

    99%

    Ambient temperature range

    -10 °C~50 °C, derating if the temperature is above 40 °C

    Cooling method

    Air cooling

    Protection degree

    IP20/IP21

    Altitude

    Below 1000m; above 1% for every additional 100m.

    Standard

    CE/ROHS


    Model Range

    Drive model

    Max DC input current (A)

    Rated output current (A)

    Applicable water pump (kW)

    VFD500M-40T00150-PV

    6.1

    3.7

    1.5

    VFD500M-40T00220-PV

    7.1

    5

    2.2

    VFD500M-40T00400-PV

    16.5

    9.4

    4

    VFD500M-40T00550-PV

    23.9

    13

    5.5

    VFD500M-40T00750-PV

    30.6

    17

    7.5

    VFD500-40T00150-PV

    6.1

    3.7

    1.5

    VFD500-40T00220-PV

    7.1

    5

    2.2

    VFD500-40T00400-PV

    16.5

    9.4

    4

    VFD500-40T00550-PV

    23.9

    13

    5.5

    VFD500-40T00750-PV

    30.6

    17

    7.5

    VFD50040T01100-PV

    39.2

    25

    11

    VFD500-40T01500-PV

    49.0

    32

    15

    VFD500-40T01850-PV

    57

    37

    18.5

    VFD500-40T02200-PV

    69

    45

    22

    VFD500-40T03000-PV

    91

    60

    30

    VFD500-40T03700-PV

    114

    75

    37

    VFD500-40T04500-PV

    146

    90

    45

    VFD500-40T05500-PV

    190

    112

    55

    VFD500-40T07500-PV

    237

    152

    75

    VFD500-40T09000-PV

    273

    176

    90

    VFD500-40T11000-PV

    319

    210

    110

    VFD500-40T13200-PV

    389

    253

    132

    220V single phase or three phase level

    VFD500-20T00075-PV

    6.7

    4.5

    0.75

    VFD500-20T00150-PV

    9.9

    7

    1.5

    VFD500-20T00220-PV

    14.1

    10.6

    2.2

    VFD500-20T00400-PV

    22.6

    17

    4

    VFD500M-20T00150-PV

    9.9

    7

    1.5

    VFD500M-20T00220-PV

    14.1

    10.6

    2.2


    Support GPRS


    Product Application

    0.75KW-4KW Single Phase Solar Pump Inverter For Solar Irrigation System

    0.75KW-4KW Single Phase Solar Pump Inverter For Solar Irrigation System

    0.75KW-4KW Single Phase Solar Pump Inverter For Solar Irrigation System

    FAQ:

    1. What should be noticed when installing inverter?
    Put the product in a place where is well ventilate, cool, dry and water-proof. Do not stress or put foreign objects into the inverter. Remember to turn on the inverter before turn on the appliance.

    2. Where is your factory located?
    Our factory is located in Shenzhen, China, you are very welcome to visit our company.
    Please feel free to contact us if you need information on road conditions or directions.

    3. If pump is 60HZ frequency, how to set max frequency?

    Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.
    Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single phase with capacitor, set P00.11=22; If your motor is single phase without capacitor, set P00.11=32