Sign In | Join Free | My himfr.com
Home > MPPT VFD Solar Pump Inverter >

Protect Your Pump with MPPT VFD Solar Pump Inverter s Reversing Method

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Protect Your Pump with MPPT VFD Solar Pump Inverter s Reversing Method from wholesalers
     
    Buy cheap Protect Your Pump with MPPT VFD Solar Pump Inverter s Reversing Method from wholesalers
    • Buy cheap Protect Your Pump with MPPT VFD Solar Pump Inverter s Reversing Method from wholesalers
    • Buy cheap Protect Your Pump with MPPT VFD Solar Pump Inverter s Reversing Method from wholesalers
    • Buy cheap Protect Your Pump with MPPT VFD Solar Pump Inverter s Reversing Method from wholesalers
    • Buy cheap Protect Your Pump with MPPT VFD Solar Pump Inverter s Reversing Method from wholesalers

    Protect Your Pump with MPPT VFD Solar Pump Inverter s Reversing Method

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-PV
    Certification : CE
    Price : Negotiable
    Payment Terms : T/T, PayPal, Western Union, L/C
    Supply Ability : 15000pcs per Month
    Delivery Time : 3 days, depend on the order quantity
    • Product Details
    • Company Profile

    Protect Your Pump with MPPT VFD Solar Pump Inverter s Reversing Method


    380V 400V 11kw 15kw MPPT VFD Solar Pump Inverter With LCD Display


    Product Features:


    Multiple pump motors with a single drive control


    Standard asynchronous motors as well as more efficient permanent magnet motors.


    Pump-specific protection


    Built-in flow measurement and sensorless flow calculation. Dry run detection can be configured to pause the pumping to protect the pump. Pump cleaning in reversing method can be programmed to maximize the pump operation.


    Electrical Specifications



    220V

    380V

    Max input DC voltage

    450V

    810V

    DC voltage range

    150~450VDC

    300~810VDC

    Normal working DC voltage

    260V-400V

    400V-650V

    Recommended input mppt voltage

    330V

    550V

    MPPT efficiency

    >99%

    Rated output voltage

    1/3-phase 220VAC

    3-phase 380-480VAC

    Output frequency range

    50/60Hz

    Max efficiency of the machine

    99%

    Ambient temperature range

    -10 °C~50 °C, derating if the temperature is above 40 °C

    Cooling method

    Air cooling

    Protection degree

    IP20/IP21

    Altitude

    Below 1000m; above 1% for every additional 100m.

    Standard

    CE/ROHS


    Solar Pump Inverter Model


    Drive model

    Max DC input current (A)

    Rated output current (A)

    Applicable water pump (kW)

    VFD500M-40T00150-PV

    6.1

    3.7

    1.5

    VFD500M-40T00220-PV

    7.1

    5

    2.2

    VFD500M-40T00400-PV

    16.5

    9.4

    4

    VFD500M-40T00550-PV

    23.9

    13

    5.5

    VFD500M-40T00750-PV

    30.6

    17

    7.5

    VFD500-40T00150-PV

    6.1

    3.7

    1.5

    VFD500-40T00220-PV

    7.1

    5

    2.2

    VFD500-40T00400-PV

    16.5

    9.4

    4

    VFD500-40T00550-PV

    23.9

    13

    5.5

    VFD500-40T00750-PV

    30.6

    17

    7.5

    VFD50040T01100-PV

    39.2

    25

    11

    VFD500-40T01500-PV

    49.0

    32

    15

    VFD500-40T01850-PV

    57

    37

    18.5

    VFD500-40T02200-PV

    69

    45

    22

    VFD500-40T03000-PV

    91

    60

    30

    VFD500-40T03700-PV

    114

    75

    37

    VFD500-40T04500-PV

    146

    90

    45

    VFD500-40T05500-PV

    190

    112

    55

    VFD500-40T07500-PV

    237

    152

    75

    VFD500-40T09000-PV

    273

    176

    90

    VFD500-40T11000-PV

    319

    210

    110

    VFD500-40T13200-PV

    389

    253

    132

    220V single phase or three phase level

    VFD500-20T00075-PV

    6.7

    4.5

    0.75

    VFD500-20T00150-PV

    9.9

    7

    1.5

    VFD500-20T00220-PV

    14.1

    10.6

    2.2

    VFD500-20T00400-PV

    22.6

    17

    4

    VFD500M-20T00150-PV

    9.9

    7

    1.5

    VFD500M-20T00220-PV

    14.1

    10.6

    2.2


    Product Application

    Protect Your Pump with MPPT VFD Solar Pump Inverter s Reversing Method

    Protect Your Pump with MPPT VFD Solar Pump Inverter s Reversing Method

    FAQ:

    1. What's the different between frequency inverter and solar pump inverter?


    Frequency inverter is only accept AC input, it’s widely used in automated machines. But solar pump inverter not only accept AC input but also can connect with solar panel to accept DC input, it more save power, mainly used in solar pumping system.

    2. What should be noticed when installing inverter?


    Put the product in a place where is well ventilate, cool, dry and water-proof. Do not stress or put foreign objects into the inverter. Remember to turn on the inverter before turn on the appliance.

    3. Do we need to set the parameter before using?


    No need, our preset parameters can already meet your normal use.
    And our inverter is AI intelligent working.
    If you need to adjust the parameters yourself, you can do it in a few simple steps.

    Quality Protect Your Pump with MPPT VFD Solar Pump Inverter s Reversing Method for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Veikong Electric Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)