Sign In | Join Free | My himfr.com
Home > Motor Soft Starter >

VKS-8000 Advanced Start and Stop Control Functions for Optimal Motor Performance

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap VKS-8000 Advanced Start and Stop Control Functions for Optimal Motor Performance from wholesalers
     
    Buy cheap VKS-8000 Advanced Start and Stop Control Functions for Optimal Motor Performance from wholesalers
    • Buy cheap VKS-8000 Advanced Start and Stop Control Functions for Optimal Motor Performance from wholesalers
    • Buy cheap VKS-8000 Advanced Start and Stop Control Functions for Optimal Motor Performance from wholesalers
    • Buy cheap VKS-8000 Advanced Start and Stop Control Functions for Optimal Motor Performance from wholesalers

    VKS-8000 Advanced Start and Stop Control Functions for Optimal Motor Performance

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VKS6000
    Certification : CE
    Price : Negotiable
    Payment Terms : Western Union, T/T, L/C, D/A, D/P, PayPal
    Supply Ability : 15000pcs per Month
    Delivery Time : 3 days, depend on the order quantity
    • Product Details
    • Company Profile

    VKS-8000 Advanced Start and Stop Control Functions for Optimal Motor Performance

    132kw 160kw 185kw 200kw bulit in Bypass Soft Starter for ac motor protection

    Product feature

    VKS-8000 is a highly intelligent, very reliable and easy to use soft starter. The newly designed functions of VKS-8000 are used for quick setting or more personalized control.

    It's a perfect solution. Its performance includes:

    Large LCD screen that can display feedback information in Chinese and English languages, other languages can be customized.

    Remotely installable operation panel.

    Intuitive programming.

    Advanced start and stop control functions.

    A series of motor protection functions.

    Extensive performance monitoring and event logging.

    Real - time language display

    VEIKONG hopes to make your work easy and worry-free, so VKS- 8000 displays feedback information in real language, you don't have to check the code to understand what happened. With the help of real-time metering display and 10 event log records with time- stamped operation and performance details, tracking motor performance has never been easier.

    Graphical display

    With an optional panel mounting kit, the panel is easily mounted outside the cabinet.

    If multiple soft starters are installed in a single cabinet to facilitate centralized control in one place, all relevant information can be obtained.

    Multiple monitors can also be mounted side by side to quickly diagnose problems.

    (after installation, the protection level is IP65)


    Removable connectors and unique connectors

    With plug - and - pull control wiring bar, it is easy to install.Simply unplug each wiring bar and reinsert the wiring bar after connecting.

    Cables can be arranged using VKS-8000 flexible cable routing, which can be run from top, left or bottom.


    Bypass contactor

    No need to install the external bypass contactor, the new built-in bypass contactor, compared with the ordinary AC contactor, performance improved by 3 times, heat dissipation 2.6 times, safety 25%, energy saving 20% service life up to 100,000 times.


    Technical Specification

    ItemDescription
    Input Power SupplyInput VoltageThree-phase 380V/480V/660 AC
    Frequency50/60Hz
    Adaptive MotorSquirrel-cage three-phase asynchronous motor
    Starting TimesIt is recommended not to exceed 20 times per hour.



    Control Mode

    (1) Operation panel control.

    (2) Operation panel + external control.

    (3) External control.

    (4) External control + COM control.

    (5) Operation panel + external + COM control.

    (6) Operation panel + COM control.

    (7) COM control.

    (8) No start or stop operation.


    Start Mode

    (1) Current-limiting to start.

    (2) Voltage ramp to start.

    (3) Torque control + current-limiting to start.

    (4) Torque control + voltage ramp to start.

    (5) Current ramp to start.

    (6) Voltage current-limiting double closed-loop start.

    Stop Mode

    (1) Soft stop.

    (2) Free stop.






    Protective Function

    (1) Open loop protection for external instantaneous stop terminals.

    (2) Over-heat protection for soft starter.

    (3) Protection for too long starting time.

    (4) Input open phase protection.

    (5) Output open phase protection.

    (6) Unbalanced three-phase protection.

    (7) starting over current protection.

    (8) Running overload protection.

    (9) Under voltage protection for power voltage.

    (10) Overvoltage protection for power voltage.

    (11) Protection for fault parameter setting.

    (12) Load short circuit protection.

    (13) Auto restart or incorrect wiring protection.

    (14) Incorrect wiring protection of external control stop terminals.


    Ambient

    Place to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
    Altitude

    Below 1000M. It have to rise the rate power when the altitude is more than 1000M.

    Temperature-20 +45 C
    Humidity90%RH without dew condensation.
    Vibration<0.5G
    StructureProtection ClassIP20
    Cooling PatternFans cooling.


    Product Application

    VKS-8000 Advanced Start and Stop Control Functions for Optimal Motor PerformanceVKS-8000 Advanced Start and Stop Control Functions for Optimal Motor PerformanceVKS-8000 Advanced Start and Stop Control Functions for Optimal Motor Performance



    Quality VKS-8000 Advanced Start and Stop Control Functions for Optimal Motor Performance for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Veikong Electric Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)