Sign In | Join Free | My himfr.com
Home > Variable Frequency Inverters >

0.75kw-710kw CNC Machine Inverter CNC Spindle VFD Positional Control

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 0.75kw-710kw CNC Machine Inverter CNC Spindle VFD Positional Control from wholesalers
     
    Buy cheap 0.75kw-710kw CNC Machine Inverter CNC Spindle VFD Positional Control from wholesalers
    • Buy cheap 0.75kw-710kw CNC Machine Inverter CNC Spindle VFD Positional Control from wholesalers
    • Buy cheap 0.75kw-710kw CNC Machine Inverter CNC Spindle VFD Positional Control from wholesalers

    0.75kw-710kw CNC Machine Inverter CNC Spindle VFD Positional Control

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 15000pcs per Month
    Delivery Time : 3 days, depend on the order quantity
    • Product Details
    • Company Profile

    0.75kw-710kw CNC Machine Inverter CNC Spindle VFD Positional Control

    VFD spindle motor inverter frequency inverters VFD for CNC machine
    VEIKONG hot selling VFD
    VFD500M is high performance vector control mini vfd
    VFD500 is high performacne general vfd
    VFD550 is high perfromance special vfd with positional control.
    VFD530 is high performance special vfd with lifting function, support 2 PID, support Synchronous and asynchronous motors
    VFD500-PV is solar pump inverter.
    VFD510 is IP65 inverter

    Why choose VEIONG:


    1, 180% torque at 0.25hz;

    2, Vector control with open-loop,closed-loop control;

    3, Automatically identify the motor parameters,self-learning;

    4, Install PID,main spindle control for CNC lathe;

    5, Modbus communication protocol,RS485 communication,CANlink

    6, Simple PLC and multistage speed;

    7, Speed tracking function;

    8, Carrier frequency automatic adjustment;

    9, Pendulum frequency;

    10,Various protection mechanisms (over current/over voltage/overload, overheating, etc),

    to protect the inverter and motor.


    Hardware features

    • Dual CPU processing, more precise control
    • Using the latest generation IGBT
    • 0.4k~22kW with standard inner brake unit
    • Inner EMC C3 filter with breakpoint design, convenient for access and disconnection, meet different
    • PCBA coating process, increase environment adaptability
    • Unique control terminals: simple electronic switch set to complete the conversion between source and sink of I/O terminals
    • Reference (current) loose, trip or not could be selected
    • IGBT thermal design
    • Wireless fan block design, easy to replace or maintain
    • Connecting auxiliary fan makes the drive suitable for worse environment

    VFD500 parameter distribution list


    ClassificationParameter groupPage
    Common parameters00:Basic functionPage 30
    01:Frequency source selectionPage 32
    02:Start and stopPage 37
    03:Ramp and S curvePage 39
    04: Analog and pulse inputPage 41
    05:Analog and pulse outputPage 45
    06: Multi-function Digital input (DI)Page 46
    07: Multi-function Digital output(DO)Page 49
    08:Digital Output settingPage 51
    Motor control10:Encoder typePage 53
    11:Motor1 parmeterPage 54
    12:Motor1 VFcontrol parameterPage 56
    13:Motor1 Vector controlparameterPage 58
    14:Torque controlPage 59
    16:Energy saving controlPage 61
    Display and protection20:User-defined parametersPage 62
    21:Keypad and displayPage 63
    22:AC Drive configurationPage 65
    23:Drive protection function settingPage 67
    24:Motor protection parameterPage 70
    25:Fault tracking parameterPage 72
    26:Fault recording parameterPage 72
    27:Monitoring parameterPage 74
    Communication30:Modbus communicationPage 75
    Application40:Process PID FunctionPage 77
    41:Sleep functionPage 81
    42:Simple PLCPage 82
    43:Programmable delay unitPage 84
    44:Comparator and logic unit/controllerPage 86
    45:Multifunction counterPage 90
    Motor 260:Motor2 basic parameterPage 91
    61:Motor2 parameterPage 91
    62:Motor2 VF control parameterPage 92
    63:Motor2 vector control parameterPage 92

    Techincal Parameters:


    ItemSpecifiation
    InputInuput Voltage

    1phase/3phase 220V:200V~240V

    3 phase 380V-480V:380V~480V

    Allowed Voltage fluctuation range-15%~10%
    Input frequency50Hz / 60Hz,fluctuation less than 5%
    OutputOutput Voltage3phase:0~input voltage
    Overload capacity

    General purpose application:60S for 150% of the rated current

    Light load application:60S for 120% of the rated current

    ControlControl mode

    V/f control

    Sensorless flux vector control without PG card(SVC)

    Sensor speed flux vector control with PG card (VC)

    Operating modeSpeed control,Torque control(SVC and VC)
    Speed range

    1:100 (V/f)

    1:200( SVC)

    1:1000 (VC)

    Speed control accuracy

    ±0.5% (V/f)

    ±0.2% (SVC)

    ±0.02% (VC)

    Speed response

    5Hz(V/f)

    20Hz(SVC)

    50Hz(VC)

    frequency range

    0.00~600.00Hz(V/f)

    0.00~200.00Hz(SVC)

    0.00~400.00Hz(VC)

    Input frequency resolution

    Digital setting: 0.01 Hz

    Analog setting: maximum frequency x 0.1%

    Startup torque

    150%/0.5Hz(V/f)

    180%/0.25Hz(SVC)

    200%/0Hz(VC)

    Torque control accuracy

    SVC:within 5Hz10%,above 5Hz5%

    VC:3.0%

    V/f curve

    V / f curve type: straight line, multipoint, power function, V / f separation;

    Torque boost support: Automatic torque boost (factory setting), manual torque boost

    Frequency giving ramp

    Support linear and S curve acceleration and deceleration;

    4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

    DC bus voltage control

    Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;


    Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure


    VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

    VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

    Carrier frequency1kHz~12kHz(Varies depending on the type)
    Startup methodDirect start (can be superimposed DC brake); speed tracking start
    Stop methodDeceleration stop (can be superimposed DC braking); free to stop
    Maincontrol functionJog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parameters free switching, software swap output wiring, terminals UP / DOWN
    FunctionKeypadLED Digital keyboard and LCD keypad(option)
    communication

    Standard:

    MODBUS communication

    Option:Profibus-DP and CAN OPEN

    PG cardIncremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card
    Input terminal

    Standard:

    5 digital input terminals, one of which supports high-speed pulse input up to 50kHz;

    2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input;

    Option card:

    4 digital input terminals

    2 analog input terminals.support-10V-+10V voltage input

    Output terminal

    standard:

    1 digital output terminal;

    1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output;

    1 relay output terminal(second relay is an option )

    2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output;

    Option card: 4 digital output terminals

    ProtectionRefer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function
    EnvironmentInstallation locationIndoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
    Altitude0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m
    Ambient temperature-10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C
    HumidityLess than 95%RH, without condensing
    VibrationLess than 5.9 m/s2 (0.6 g)
    Storage temperature-20°C ~ +60°C
    OthersInstallationWall-mounted, floor-controlled cabinet, transmural
    Protection levelIP20
    cooling methodForced air cooling



    VEIKONG VFD application:


    VEIKONG VFD replace famous brands


    Mode Range

    Model

    Power capacity

    (KVA)

    Input current

    (A)

    Output current(A)

    Adaptable Motor

    (KW)

    SIZEBrake Unit
    Heavy loadLight load
    Three phase: 380-480V,50/60Hz
    VFD500-R75GT4B1.53.42.54.20.75SIZE AInternal
    VFD500-1R5GT4B354.25.61.5
    VFD500-2R2GT4B45.85.69.42.2
    VFD500-4R0G/5R5PT4B5.910.59.413.03.7
    VFD500-5R5G/7R5PT4B8.914.613.017.05.5SIZE B
    VFD500-7R5G/011PT4B1120.517.023.07.5
    VFD500-011G/015PT4B1726.025.031.011SIZE CInternal
    VFD500-015G/018PT4B2135.032.037.015
    VFD500-018G/022PT4B2438.537.045.018.5SIZE D
    VFD500-022G/030PT4B3046.545.057.022
    VFD500-030G/037PT44062.060.075.030SIZE Eoption
    VFD500-037G/045PT45076.075.087.037
    VFD500-045G/055PT46092.090.0110.045SIZE F
    VFD500-055G/075PT475113.0110.0135.055
    VFD500-075G/090PT4104157.0152.0165.075SIZE G
    VFD500-090G/110PT4112170.0176.0210.090External
    VFD500-110G/132PT4145220.0210.0253.0110SIZE H
    VFD500-132G/160PT4170258.0253.0304.0132SIZE I
    VFD500-160G/185PT4210320.0304.0360.0160
    VFD500-185G/200PT4245372.0360.0380.0185SIZE J
    VFD500-200G/220PT4250380.0380.0426.0200
    VFD500-220G/250PT4280425.0426.0465.0220SIZE K
    VFD500-250G/280PT4315479.0465.0520.0250
    VFD500-280G/315PT4350532.0520.0585.0280SIZE L
    VFD500-315G/355PT4385585.0585.0650.0315
    VFD500-355G/400PT4420638.0650.0725.0355SIZE M
    VFD500-400G/450PT4470714.0725.0820.0400
    VFD500-450G/500PT4530800.0820.0/450SIZE N
    VFD500-500G/560PT4580880.0900.0/500
    VFD500-560G/630PT4630950.0980.0/560SIZE O
    VFD500-630GT471010801120./630SIZE O
    VFD500-710GT479012001260/710SIZE O
    Single phase :220V ,50/60HZ
    VFD500-R40GS21.36.03.25.60.4SIZE AInbuilt
    VFD500-R75GS22.411.05.68.00.75SIZE A
    VFD500-1R5GS23.515.08.010.61.5SIZE A
    VFD500-2R2GS25.525.010.614.02.2SIZE A
    VFD500-4R0GS27.735.017.023.04.0SIZE B
    VFD500-5R5GS28.953.025.031.05.5SIZE C
    VFD500-7R5GS21167.032.037.07.5SIZE C