Sign In | Join Free | My himfr.com
Home > Single Phase Solar Pump Inverter >

Advanced MPPT Algorithms for 99% Efficiency in Single Phase Solar Pump Inverter

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Advanced MPPT Algorithms for 99% Efficiency in Single Phase Solar Pump Inverter from wholesalers
     
    Buy cheap Advanced MPPT Algorithms for 99% Efficiency in Single Phase Solar Pump Inverter from wholesalers
    • Buy cheap Advanced MPPT Algorithms for 99% Efficiency in Single Phase Solar Pump Inverter from wholesalers
    • Buy cheap Advanced MPPT Algorithms for 99% Efficiency in Single Phase Solar Pump Inverter from wholesalers
    • Buy cheap Advanced MPPT Algorithms for 99% Efficiency in Single Phase Solar Pump Inverter from wholesalers
    • Buy cheap Advanced MPPT Algorithms for 99% Efficiency in Single Phase Solar Pump Inverter from wholesalers

    Advanced MPPT Algorithms for 99% Efficiency in Single Phase Solar Pump Inverter

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-PV
    Certification : CE ROHS IEC
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 15000pcs per Month
    Delivery Time : 3 days, depend on the order quantity
    MOQ : Negotiable for regular client
    • Product Details
    • Company Profile

    Advanced MPPT Algorithms for 99% Efficiency in Single Phase Solar Pump Inverter

    Single phase output inverter 2hp 5hp 2.2kw 4kw mppt solar pump inverter ​


    Key Advantages:


    1. Cover voltage levels 220V AC and 380V AC.

    Support single-phase 220V and three-phase 220V/380V pumps,the power from 0.4KW to 37KW.


    2. Easy to use

    The inverters automatically start or sleep only after being connected to solar battery panels without any parameter setting.


    3. Highly reliable for using multiple protective measures

    Including PV over-voltage protection,PV polarity reverse warning,and auto derating against over-temperture,which extend product life.


    4. Use advanced MPPT algorithms,ensuring that the solar power tracking efficiency reaches 99%


    5. Models of 2.2kW or lower can be configured with boost module,meeting low-voltage work requirements.This reduces the use of solar battery panels and therefore the cost.


    6. it can implement auto switch between solar input and grid input by configuring the boost or auto switching cabinet(meeting lightning protection requirements),implementing 24-hour unattended work.


    Techincal Parameters:


    1. Wake up and sleep function parameters:


    P47.05Light detection thresholdIf the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop0Hz
    P47.06Light detection timeSee P47.05 for explanation.60s
    P47.07Light weak wake up timeAfter the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues.600s

    2. Dry runing protection function parameters:


    P24.12Dry run/Unload protection option

    0: No offload detection is performed;

    1: Enable dry run detection

    1
    P24.13Dry run/Unload detection level

    0.0 to 200.0%

    The percentage of motor rated current.

    0.0%
    P24.14Dry run Unload detection time0.000s~60.000s30.000s
    P24.15Unload detection offset frequency

    0.00Hz~Fmax

    Detection frequency=Fmax-P24.15


    5.00Hz
    P24.16Reset time of dry run protection0.0~6000.0240.0s
    P23.21Dry run detection mode

    0000:Coast stop

    1000:Fast stop

    3000:Continue to run

    0000

    3. Water full protection function parameters:


    P47.18Full water level detection channel

    0:ineffective

    1:AI1

    2:AI2

    3:AI3

    4:AI4

    Note: DI terminal function code 60-full water level detection is same with Analogue detection, and the detection time and recovery time are the same.

    0
    P47.19Full water level detection value

    0.0~100.0%


    0.0%
    P47.20Full water level detection time

    0.0~3000.0s

    When DI-60 is valid or meets the analog detection channel greater than P47.19 and maintains P47.20 time, the system reports A.Full and stops.


    10.0s
    P47.21Full water recovery time

    0.0~3000.0s

    When the condition described in P47.20 does not meet full water level detection requirement ,it will be returned to normal state after delay

    10.0s

    Support optional LCD keypad


    Support optional GPRS Module

    VEIKONG VFD500-PV 2.2KW 4KW picture:

    VEIKONG Solar pump special parameter User mode fast quick start


    Function codeNameDescriptionDefaultProperty
    47 Group solar pumping special group
    P00.03RESET

    0:NO ACTION

    11:Restore default parameter except for motor parameter and auto-tune related parameter and factory parameter

    12:Restore default to factory parameter 13:Clear tripping record

    0
    P00.06Source of the Operation Command

    0:keypad

    1:terminal

    2:communication

    Ø Command source: run,stop,forward,reverse,jog,fast brake stop.etc

    0
    P00.07Numeric frequency setting00.00Hz~maximum frequency50.00Hz
    P00.11Application Macro

    01:Output three phase 50HZ

    02:Output three phase 60hz

    21:Output single phase with capacitor 50hz

    22:Output single phase with capacitor 60hz

    31:Output single phase without capacitor 50hz

    32:Output single phase without capacitor 60hz

    00
    P01.06Maximum frequency10.00~600.00Hz50.00Hz
    P01.08Upper limit frequencyLower limit frequency-maximum frequency50.00Hz
    P07.03Relay 1 Output terminal function group(T1A T1B T1C)

    0:No function

    1:READY

    2:RUN

    3:Error1(stop fault)

    4:Error2(same as Error1 except undervoltage)

    5:Warning output(fault but in running)

    3
    P11.01AC asynchronous motor TYPE

    0:Three phase AC asynchronous motor

    1:Single phase AC asynchronous motor without starting capacitor

    0
    P11.02Motor rated power

    0.1kW~710.0kW

    Ø when power is less than 1kw ,0.75kw set to 0.8 as per round up principle ,0.55kw motor set 0.6

    Ø when change motor rated power,AC drive will automatically set other parameter of motor name plate and motor model parameter be careful to use

    Depend
    P11.03Motor rated voltage10V~2000VDepend
    P11.04Motor rated current

    P11.02<30kW:0.01A

    P11.02>=30kW:0.1A

    Depend
    P11.05Motor rated frequency1.00Hz~600.00Hz50.00Hz
    P11.06Motor rated RPM1~60000rpmDepend
    P21.00Monitoring display

    0:Standard mode (display frequency only)

    1:Automatic scrolling display(Check 3.1 in detail )it show hz,current,power and voltage

    0
    P23.15Output phase loss function0.0-30%, 0% means output phase detections shielded30%
    r27.15Accumulative running timeUnit:hour
    P47.00Solar pump Mppt function enable

    0: invalid

    The parameters behind the 47 group cannot be changed!

    1: Enable, to enable the special mppt function of the PV pump inverter


    1
    P47.01

    Solar pump control mode


    Units digit’s: Startup mode

    0: Manual start, the start mode is determined by P00.06;

    1: automatic start,

    When P00.06 change, the association changes here.

    P00.06=0, when inverter starts and stops by keypad control, it is automatically modified to 1-automatic start

    P00.06=1, when inverter starts and stops by terminal control.it is automatically changed to 0-manual start

    Ten digit’s: MPPT function

    0: MPPT is disabled; CVT control is used (voltage is given as P47.04).

    1: Enable MPPT.

    11
    P47.03Automatic start timingIn auto start mode, set the time from power on to start. It is also waiting time to start600
    P47.04MPPT starting voltage

    Set the starting voltage of the MPPT algorithm.

    When the MPPT function is disabled, this value is the reference voltage.

    305V(530V)
    P47.05Light detection thresholdIf the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop0Hz
    P47.06Light detection timeSee P47.05 for explanation.60s
    P47.07Light weak wake up timeAfter the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues.600s
    P47.08MPPT tracking step lengthThe amount of change in the bus voltage during an MPPT cycle. The larger the value, the faster the maximum power point is found, but the lower the accuracy of the maximum power point.2V
    P47.09Regulator proportional gain0.001~1.00 It is for immediate response speed, it is not recommended to change0.05
    P47.10Regulator integral gain0.001~0.100 tracking response.it is not recommended to change0.05
    P47.28Starting coefficient0.000~1.0000.850
    P47.30Fast speed function

    Unit digit:fast starting

    0:Disable 1:Enable

    Ten digit:Fast mppt tracking

    0:Disable 1:Enable

    11