Sign In | Join Free | My himfr.com
Home > Single Phase Solar Pump Inverter >

Advanced Single Phase Solar Pump Inverter 220V 0.75KW 1HP 1.5KW 2HP for Solar Water Solutions

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Advanced Single Phase Solar Pump Inverter 220V 0.75KW 1HP 1.5KW 2HP for Solar Water Solutions from wholesalers
     
    Buy cheap Advanced Single Phase Solar Pump Inverter 220V 0.75KW 1HP 1.5KW 2HP for Solar Water Solutions from wholesalers
    • Buy cheap Advanced Single Phase Solar Pump Inverter 220V 0.75KW 1HP 1.5KW 2HP for Solar Water Solutions from wholesalers
    • Buy cheap Advanced Single Phase Solar Pump Inverter 220V 0.75KW 1HP 1.5KW 2HP for Solar Water Solutions from wholesalers

    Advanced Single Phase Solar Pump Inverter 220V 0.75KW 1HP 1.5KW 2HP for Solar Water Solutions

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-PV
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 15000pcs per Month
    Delivery Time : 3 days, depend on the order quantity
    • Product Details
    • Company Profile

    Advanced Single Phase Solar Pump Inverter 220V 0.75KW 1HP 1.5KW 2HP for Solar Water Solutions

    Mppt efficiency 99% solar pump inverter 220v 0.75kw 1hp 1.5kw 2hp


    Model Range


    Drive ModelRelated VoltageMax DC input voltage (V)Rated output current (A)Applicable water pump (KW)SIZE
    VFD500M-20T00150-PV220V80071.5SIZE A
    VFD500M-20T00220-PV220V80010.62.2SIZE A
    VFD500M-40T00150-PV380V8004.21.5SIZE A
    VFD500M-40T00220-PV380V80062.2SIZE A
    VFD500-20T00150-PV220V80071.5SIZE A
    VFD500-20T00220-PV220V80010.62.2SIZE A
    VFD500-20T00400-PV220V800174SIZE A
    VFD500-40T00150-PV380V8004.21.5SIZE A
    VFD500-40T00220-PV380V80062.2SIZE A
    VFD500-40T00400-PV380V8009.44SIZE A
    VFD500-40T00550-PV380V800135.5SIZE B
    VFD500-40T00750-PV380V800177.5SIZE B
    VFD500-40T01100-PV380V8002511SIZE C
    VFD500-40T01500-PV380V8003215SIZE C
    VFD500-40T01850-PV380V8003818.5SIZE D
    VFD500-40T02200-PV380V8004622SIZE D
    VFD500-40T03000-PV380V8006030SIZE E
    VFD500-40T03700-PV380V8007537SIZE E
    VFD500-40T04500-PV380V8009645SIZE F
    VFD500-40T05500-PV380V80011255SIZE F
    VFD500-40T07500-PV380V80015075SIZE G
    VFD500-40T09000-PV380V80017690SIZE G
    VFD500-40T11000-PV380V800210110SIZE H
    VFD500-40T13200-PV380V800253132SIZE I
    VFD500-40T16000-PV380V800304160SIZE I
    VFD500-40T18500-PV380V800340185SIZE J
    VFD500-40T20000-PV380V800377200SIZE J

    Key Advantages:


    1, The power range is from 220V 0.75kw to75kw, and 380v 0.75kw to 160kw


    1, MPPT control mode, adjust the output frequency to the appropriate frequency in real-time.


    2,,Adjust water outflow of pumps quickly on basis of sunlight intensity change.


    3,With functions of light weak protection, dry run and low voltage,full water warning, overvoltage and overtemperature protection.


    4, New keyboard design, support optional LCD keypad, simple appearance, and easy operation.


    5,Automatic running without any commisioning in keypad control and GPRS monitoring option(as option).


    6,Support PMSM pump


    Techincal Parameters:


    1. Wake up and sleep function parameters:


    P47.05Light detection thresholdIf the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop0Hz
    P47.06Light detection timeSee P47.05 for explanation.60s
    P47.07Light weak wake up timeAfter the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues.600s

    2. Dry runing protection function parameters:


    P24.12Dry run/Unload protection option

    0: No offload detection is performed;

    1: Enable dry run detection

    1
    P24.13Dry run/Unload detection level

    0.0 to 200.0%

    The percentage of motor rated current.

    0.0%
    P24.14Dry run Unload detection time0.000s~60.000s30.000s
    P24.15Unload detection offset frequency

    0.00Hz~Fmax

    Detection frequency=Fmax-P24.15


    5.00Hz
    P24.16Reset time of dry run protection0.0~6000.0240.0s
    P23.21Dry run detection mode

    0000:Coast stop

    1000:Fast stop

    3000:Continue to run

    0000

    3. Water full protection function parameters:


    P47.18Full water level detection channel

    0:ineffective

    1:AI1

    2:AI2

    3:AI3

    4:AI4

    Note: DI terminal function code 60-full water level detection is same with Analogue detection, and the detection time and recovery time are the same.

    0
    P47.19Full water level detection value

    0.0~100.0%


    0.0%
    P47.20Full water level detection time

    0.0~3000.0s

    When DI-60 is valid or meets the analog detection channel greater than P47.19 and maintains P47.20 time, the system reports A.Full and stops.


    10.0s
    P47.21Full water recovery time

    0.0~3000.0s

    When the condition described in P47.20 does not meet full water level detection requirement ,it will be returned to normal state after delay

    10.0s

    Support optional LCD keypad


    Support optional GPRS Module

    Product application pictures