Sign In | Join Free | My himfr.com
Home > VFD Variable Frequency Drive >

90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor from wholesalers
     
    Buy cheap 90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor from wholesalers
    • Buy cheap 90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor from wholesalers
    • Buy cheap 90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor from wholesalers
    • Buy cheap 90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor from wholesalers
    • Buy cheap 90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor from wholesalers

    90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-045G/055GT4B
    Certification : CE, ROHS
    Price : Please contact quotation
    Payment Terms : T/T, Western Union, L/C
    Supply Ability : 1000 units per week
    Delivery Time : depends on quantities
    • Product Details
    • Company Profile

    90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor

    45kw 60hp ac drive inverter vfd for pump fan air compressor vfd


    1, With inside EMC C3 filter and building-block design for IO extension card and different kinds of PG card
    2, Top performance in our industry which represent in torque in less than 1hz 0.5hz 0.25hz 0.1hz and 0hz
    it can compare with any domestic chinese brand for output torque.
    3, Smooth running and stability, support optional LCD keypad and dual display keypad. support PC tools.
    4, Support modbus485, canopen, profinet communciation.
    5, Low noise on motor and fast response for 0.1S acceleration and deceleration without dead zone
    6, Reverse and forward free switching
    7, Sleeping function and energy saving function as well as in built PLC programming
    8, Tension control and torque mode control
    9, Support two group motor parameters which can realize two motor switching control
    ItemSpecifiation
    InputInuput Voltage

    1phase/3phase 220V:200V~240V

    3 phase 380V-480V:380V~480V

    Allowed Voltage fluctuation range-15%~10%
    Input frequency50Hz / 60Hz,fluctuation less than 5%
    OutputOutput Voltage3phase:0~input voltage
    Overload capacity

    General purpose application:60S for 150% of the rated current

    Light load application:60S for 120% of the rated current

    ControlControl mode

    V/f control

    Sensorless flux vector control without PG card(SVC)

    Sensor speed flux vector control with PG card (VC)

    Operating modeSpeed control,Torque control(SVC and VC)
    Speed range

    1:100 (V/f)

    1:200( SVC)

    1:1000 (VC)

    Speed control accuracy

    ±0.5% (V/f)

    ±0.2% (SVC)

    ±0.02% (VC)

    Speed response

    5Hz(V/f)

    20Hz(SVC)

    50Hz(VC)

    frequency range

    0.00~600.00Hz(V/f)

    0.00~200.00Hz(SVC)

    0.00~400.00Hz(VC)

    Input frequency resolution

    Digital setting: 0.01 Hz

    Analog setting: maximum frequency x 0.1%

    Startup torque

    150%/0.5Hz(V/f)

    180%/0.25Hz(SVC)

    200%/0Hz(VC)

    Torque control accuracy

    SVC:within 5Hz10%,above 5Hz5%

    VC:3.0%

    V/f curve

    V / f curve type: straight line, multipoint, power function, V / f separation;

    Torque boost support: Automatic torque boost (factory setting), manual torque boost

    Frequency giving ramp

    Support linear and S curve acceleration and deceleration;

    4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

    DC bus voltage control

    Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;


    Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure


    VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

    VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

    Carrier frequency1kHz~12kHz(Varies depending on the type)
    Startup method

    Direct start (can be superimposed DC brake); speed tracking start


    VEIKONG inverter work together with famous brands


    Modbus and Canopen communication parameter


    30 Group Modbus communication parameter
    P30.00Communication type

    0:Modbus;

    1:Canopen

    0
    P30.01Drive Address

    1~247

    Different slaves on the same network should set different local addresses;

    0 is the broadcast address, all slave inverters can be identified

    1
    P30.02Modbus baud rate

    0:1200 bps; 1:2400 bps

    2:4800 bps; 3:9600 bps

    4:19200 bps; 5:38400 bps

    6:57600 bps; 7:115200 bps

    3
    P30.03Modbus data format

    0: 1-8-N-1

    (1 start bit +8 data bits +1 stop bits )

    1: 1-8-E-1

    (1start bit +8 data bits +1 even parity +1 stop bit)

    2: 1-8-0-1

    (1 star bit+8 data bits +1odd parity+1 stop bits)

    3: 1-8-N-2

    (1 star bit+8 data bits+2 stop bits)

    4: 1-8-E-2

    (1 star bits+8 data bit+1 even parity+2 stop bits)

    5: 1-8-0-2

    (1 start bit +8 data bits+1 odd parity+2 stop bits)

    0
    P30.04Modbus response delay1~20msThe delay time of the local to answer the master2ms
    P30.05Modbus overtime0.0s(disabled)~60.0s(works for master-slave system) When this function code effective,if slave do not receive data from master overtime,it will trip as Er.4850.0s
    r30.06Number of frames received by ModbusEach time a frame is received, this value is incremented by 1,0 to 65535 cycles.-
    r30.07Number of frames that Modbus has sentEach time a frame is sent, this value is incremented by 1,0 to 65,536 cycles.-
    r30.08Number of error frames received by ModbusEach time an CRC error frame is received, this value is incremented by 1,0 to 65535 cycles; it can be used to judge the degree of communication interference.-
    P30.09Modbus master-slave option0: Slave
    1: Master(sent by broadcast )
    0
    P30.10Slave memory when inverter as master1~9 corresponds to 0x7001~0x70091
    P30.11Data sent by Master

    0:output frequency

    1:set frequency

    2:output torque

    3:set torque

    4:PID setting

    5:PID feedback

    6:output current

    0
    P30.12Sending interval of Master0.010~10.000sAs a master, after sending one frame of data, the next frame of data is sent after this delay.0.1s
    P30.13Receiving proportaionality factor of slave-10.000~10.000The values of slave registers 0x7001 and 0x7002 take effect after passing through this scaling factor1.00
    P30.14Communication special register speed unit

    0: 0.01%

    1: 0.01Hz

    2: 1Rpm

    Some units of specific communication registers can be set by this parameter. See Appendix A for details.

    0
    P30.15Modbus response characteristics

    When the format of the received frame is a write register, this parameter can be set to reply to the host.

    0: Reply to the host (standard Modbus protocol)

    1: Do not reply to the host (non-standard Modbus protocol)

    0
    31 Group Canopen communication parameter
    P31.00CANopen communication address1 ~ 1271
    P31.01CANopen Baud rate

    0:100k

    1:125k

    2:250k

    3:500k

    4:1M

    3
    P31.02CANopen overtime1ms ~ 20ms4ms
    r31.07CANopen version numberDisplay the version number of the CANopen card-
    r31.08CANopen Working status

    0: Initialisation status

    1: Disconnected

    2: Connecting/Preparing-

    3: Stopped

    4: Operational status

    5: Pre_operational

    -
    r31.10CANopen receive error countThe number of error frames received by CANopen is not saved after power off-
    r31.11CANopen send error countThe number of frames sent by CANopen is not saved after power off-
    r31.12CANopen receive frame numberThe number of frames received by CANopen is not saved after power off-
    r31.14CANopen send frame numberThe number of frames sent by CANopen is not saved after power off-
    Quality 90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Veikong Electric Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)