Sign In | Join Free | My himfr.com
Home > 3 Phase Solar Pump Inverter >

Precise MPPT VFD 3 Phase Solar Pump Inverter 132kw 160kw 185kw 200kw

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Precise MPPT VFD 3 Phase Solar Pump Inverter 132kw 160kw 185kw 200kw from wholesalers
     
    Buy cheap Precise MPPT VFD 3 Phase Solar Pump Inverter 132kw 160kw 185kw 200kw from wholesalers
    • Buy cheap Precise MPPT VFD 3 Phase Solar Pump Inverter 132kw 160kw 185kw 200kw from wholesalers

    Precise MPPT VFD 3 Phase Solar Pump Inverter 132kw 160kw 185kw 200kw

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-PV
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 15000pcs per Month
    Delivery Time : 3 days, depend on the order quantity
    • Product Details
    • Company Profile

    Precise MPPT VFD 3 Phase Solar Pump Inverter 132kw 160kw 185kw 200kw

    Precise MPPT VFD 3 Phase Solar Pump Inverter 132kw 160kw 185kw 200kw


    132kw 160kw 185kw 200kw Solar Vfd pump Controller Three Phase inverter


    Electrical Specifications and Power degree


    220V380V
    Max input DC voltage450V810V
    DC voltage range150~450VDC300~810VDC
    Normal working DC voltage260V-400V400V-650V
    Recommended input mppt voltage330V550V
    MPPT efficiency>99%
    Rated output voltage1/3-phase 220VAC3-phase 380-480VAC
    Output frequency range50/60Hz
    Max efficiency of the machine99%
    Power range220v 0.75kw to 75kw, 380v 1.5kw-160kw
    Cooling methodAir cooling
    Protection degreeIP20/IP65
    AltitudeBelow 1000m; above 1% for every additional 100m.
    StandardCE/ROHS

    VEIKONG VFD500-PV features:


    1Robust MPPT & Precise MPPT.
    2Special solar pump inverter macro, easy to operate parameters
    3Plug and play mode: Only requests correct wiring, motor parameter setting and sleep frequency setting.
    4Senor mode: Precise MPPT function, dry run protection, pump cleaning function, reduce pump clogging at dusk/rainy days.
    5Expert mode: Water level control, pipe system overpressure protection, flow calculation, multi-step water supply, pressure limit under solar power supply, constant speed mode under AC power supply.
    6Support both DC solar input and AC power input simutaneously.
    7Simplified commissioning;
    8Diverse input and output terminals;
    9Ambient temperature: -10°C~50°C;
    10Online and offline auto-tuning both available;

    How to start solar pump inverter?

    Make sure all cables connections of solar panel and pump motor correct and no need to set any parameter,

    If you want to set parameter, you can do as follows.


    Step 1: (Keypad control):Set motor parameter P11.02- P11.06 as per motor pump name plate If dry run protection is required,

    measure the unload protection current according to the following method.

    If dry run protection not required then miss this step and go to step 2.


    Step 2: Set other related special solar pump parameters for optimization if needed.


    Step 3: After trial run finishing, if motor pump still not output water when inverter is running more than 40 Hz.

    Please disconnect the power supply and replace any two-phase wiring of the motor.

    VFD500-PV appearance detail pictures and accessories
    GPRS
    LCD
    Output reactor

    Customer feedback about VFD500-PV performance

    Techincal Parameters:


    1. Wake up and sleep function parameters:


    P47.05Light detection thresholdIf the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop0Hz
    P47.06Light detection timeSee P47.05 for explanation.60s
    P47.07Light weak wake up timeAfter the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues.600s

    2. Dry runing protection function parameters:


    P24.12Dry run/Unload protection option

    0: No offload detection is performed;

    1: Enable dry run detection

    1
    P24.13Dry run/Unload detection level

    0.0 to 200.0%

    The percentage of motor rated current.

    0.0%
    P24.14Dry run Unload detection time0.000s~60.000s30.000s
    P24.15Unload detection offset frequency

    0.00Hz~Fmax

    Detection frequency=Fmax-P24.15


    5.00Hz
    P24.16Reset time of dry run protection0.0~6000.0240.0s
    P23.21Dry run detection mode

    0000:Coast stop

    1000:Fast stop

    3000:Continue to run

    0000