    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-PV
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 15000pcs per Month
    Delivery Time : depend on the order quantity
    • Product Details
    • Company Profile

    230VAC 400VAC 7.5kw 10hp 3 Phase Solar Pump Controller VFD MPPT Control

    230VAC 400VAC 7.5kw 10hp 3 Phase Solar Pump Controller VFD MPPT Control


    Solar VFD ac and dc input solar pump inverter 380v 4kw 5hp mppt control

    Electrical Specifications and Power degree

    220V

    380V

    Max input DC voltage

    450V

    810V

    DC voltage range

    150~450VDC

    300~810VDC

    Normal working DC voltage

    260V-400V

    400V-650V

    Recommended input mppt voltage

    330V

    550V

    MPPT efficiency

    >99%

    Rated output voltage

    1/3-phase 220VAC

    3-phase 380-480VAC

    Output frequency range

    50/60Hz

    Max efficiency of the machine

    99%

    Ambient temperature range

    -10 °C~50 °C, derating if the temperature is above 40 °C

    Cooling method

    Air cooling

    Protection degree

    IP20/IP21

    Altitude

    Below 1000m; above 1% for every additional 100m.

    Standard

    CE/ROHS



    Advantages:


    1, Suitable for single phase pump, three phase pump. Permanent magnet synchronous pump


    2, Support PV input and AC input at same time, make system work 24 hours.


    3, Built-in MPPT technology with up to 99.9% efficiency.


    4, With water level detection function, automatically regulate the pump flow to prevent dryrunning


    5, Water full protection function, when the water is full, inverter will stop.


    6, Support optional LCD keypad, you can know every parameter's meansing on display,

    and you can monitor any 5 group parmaters situation.


    7, Support optional GPRS module, you can remotely monitor the system situation.


    Accessories:

    1. GPRS (support 2g/3g/4g internet)

    It supplies water volume monitoring and operation of inverter from anywhere at anytim
    It’s convenient to visit real time and historical data via web or Android APP anytime and anywhere.
    This easy-to-use platform makes monitoring of solar pump systems simple and convenient,
    far reducing operate time and monitoring costs as well.



    2. LCD keypad

    Standard inverter are with LED keypad,LCD keypad is optional.
    LCD keypad can monitor 4 parameters at the same time. LED keypad show one parameter only.
    LCD keypad with detailed parameter explain,no need use user manual ,more user friendly.
    LCD keypad with copy and update and download function.widely used for government projects and big farms.




    3. Output Reactor

    When the distance between inverter and pump is more than 70m, you need use reactor to protect this system.


    VFD500-PV 5.5KW 7.5kw 380V inverter picture:


    Technical Questions and solutions


    1. How to achieve Automatic start after stop?

    If it is controlled by keyboard no need to set any parameter. If you want to control by external switch

    As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop


    2. How to use a float in the water tank to stop the pump if the tank is full?

    If your float signal is digital signal Use float switch to short DI 1 and com and P00.06=1


    3.Use level probe in the well for protection against dry running?

    Set P24.13=30%-40% and P24.14 P24.16 and P23.21

    If your float signal is Analog signal, Connect Ai2 and 10V and GND and set P41.00=23 and

    P41.03-P41.06



    FAQ
    1. How to achieve Automatic start after stop?
    If it is controlled by keyboard no need to set any parameter. If you want to control by external switch
    As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com
    and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop
    2. How to design solar PV water pump system?
    Key point: the rated VOC and VMP and power of the PV Array need to match the input range of
    the inverter. If needed, we will provide technical support online.
    3. How to use a float in the water tank to stop the pump if the tank is full?
    If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3